1-5 Assembly and Disassembly

1-5-1

Precautions for assembly and disassembly

(1) Precautions

Before starting disassembly, press the Power key on the operation panel to off. Make sure that the Power indicator and the
Memory indicator are off before turning off the main power switch. And then unplug the power cable from the wall outlet.
Turning off the main power switch before pressing the Power key to off may cause damage to the equipped hard disk.
When optional fax kit is installed, be sure to disconnect the modular code before starting disassembly.
When handling PWBs (printed wiring boards), do not touch parts with bare hands.
The PWBs are susceptible to static charge. Do not touch any PWB containing ICs with bare hands or any object prone to
static charge.
Use only the specified parts to replace the fuser unit thermostat. Never substitute electric wires, as the machine may be
seriously damaged.
When replacing battery on a PWB, dispose properly according to laws and regulations.
When removing the hook of the connector, be sure to release the hook.

(2) Drum

Note the following when handling or storing the drum.
When removing the drum unit, never expose the drum surface to strong direct light.
°
°
°
°
Keep the drum at an ambient temperature between 0
C/32
F and 35
C/95
F and at a relative humidity not higher than
85% RH. Avoid abrupt changes in temperature and humidity.
Avoid exposure to any substance which is harmful to or may affect the quality of the drum.
Do not touch the drum surface with any object. Should it be touched by hands or stained with oil, clean it.

(3) Toner

Store the toner container in a cool, dark place.
Avoid direct light and high humidity.