Description Of Menu 2 Functions - Ikegami HLM-2450WB Operation Manual

Full hd multi-format lcd color monitor
Table of Contents

Advertisement

4-4.Description of MENU 2 Functions
MENU2(MODE)
1.FUNCTION1 MODE
2.FUNCTION2 MODE
3.REMOTE NO.
4.CHANGE ASPECT
5.CONT VR ASSIGN
6.BACKLIGHT DIM.
7.TALLY
8.REAL SCAN
9.SDI CH LOCK
10.SDI ERROR LED
11.FORMAT DISPLAY
SET→   EXIT→
ENT
① Setting the function assignment of F1 switch
・ Set any of the following operations performed by
pressing the
switch on the front panel.
F1
< Assignment list of the F1
(Preset file change)
・FILE
・MRK SEL (Marker type change)
(Decoder Y/C separation setting change)
・COMB
・CHR UP (Chroma up ON/OFF change)
・IP MODE (IP conversion mode FIELD/FRAME
change)
(Delay H/V/H+V change)
・DELAY
・RS ON
(Same-size display ON/OFF change)
・USR MRK (USER MARKER display ON/OFF
change)
・VSC ON
(VECTOR display ON/OFF change)
・VITC ON (SDI VITC display ON/OFF change)
・WFM ON (WFM display ON/OFF change)
・PC SEL
(CM-175: PC/COMP. input change)
(CM-175: SYNC INT/EXT change)
・SYNC
・AUD CH (Channel change of embedded audio)
・BL DIM
(Backlight brightness level change)
※ PC SEL and SYNC are selectable only when the
CM-175 (option) is mounted.
※ DELAY is not operative with PC, DVI(PC) and
VBS signals. When set at DELAY, the same-size
(dot by dot) display is fixed in order to prevent
any scaling process.
・Default setting is WFM ON.
② Setting the function assignment of F2 switch
・ The function assignment is selectable in the same
way as that shown above ① by pressing the F2
switch on the front panel.
・Default setting is VITC ON.
WFM ON 
① Setting the function assignment of F 1 switch
VITC ON
② Setting the function assignment of F 2 switch
01
③ Setting the serial remote control ID number
AUTO 
④ Setting the automatic/manual aspect ratio change
CONT
⑤ Setting the assignment of "CONT" manual control
15
⑥ Setting the backlight brightness level
R/G
⑦ Setting the tally lamp indication
OFF  
⑧ Setting the same-size (dot-by-dot) display ON/OFF
OFF
⑨ Setting the SDI channel switching lock ON /OFF
ON
⑩ Setting the SDI ERROR LED display ON/OFF
⑪ Setting the format display ON/OFF/TIMER at signal switching
3SEC ON
E S C
and
F2
switches >
③ Setting the serial remote control ID number
・ Used to set the ID number (01 to 99) of the monitor.
・ The ID number is assigned to each monitor in
order to perform remote operation with the serial
remote controller (SRC-301A/Z).
・Default setting is 01.
④ Setting the automatic/manual aspect ratio change
・ Used to select the automatic setting of a preset
aspect ratio or the fixed setting for all reception
channels, when selecting any reception channel.
・ AUTO
: displayed with the set aspect ratio
for each channel
・ MANUAL : displayed with the same aspect
ratio for all channels
・Default setting is AUTO.
※ When making an aspect change in the parallel
remote mode, set to "MANUAL".
⑤Setting the assignment of "CONT" manual control
・Used to assign the function to the [CONT] control
(switch popped up).
:contrast's manual level setting
・CONT
・BL DIM. :backlight level setting .
・Default setting is CONT.
※ With setting at "BL DIM", the "6.BACKLIGHT
DIM." item automatically varies accordingly. Also
the preset data is kept intact even when the
switch is pressed.
⑥ Setting the backlight brightness level
・ When the backlight brightness level is raised, the
black level is also slightly raised. Therefore set
the backlight brightness level according to the
ambient condition.
・ This function can be assigned with the F1 F2
switch on the front panel.
・Default setting is 15.
※ The use at lower backlight brightness level
extends the life span of backlight.
- -
16

Advertisement

Table of Contents
loading

Table of Contents