How to modify the user markers
① Setting the marker display ON/OFF
MENU7(MARKER)
1.MARKER( 16:9)
SAFETY
2.→SAFETY AREA
80%
3.→ASPECT
4:3
4.→AREA IN ASPECT
80%
5.MARKER( 4:3)
SAFETY
6.→SAFETY AREA
80%
7.→ASPECT
16:9
8.ASP.MARKER MODE
MRK+SHD
9.→SHADOW LEVEL
40%
10.CENTER MARKER
OFF
11.MARKER LEVEL
80%
12.MARKER COLOR
□
13.USER MARKER
ON
14.→SETTING
EXECUTE
SET→ EXIT→
ENT
E S C
Move the cursor
② Execute the drawing mode in item 14
MENU7(MARKER)
1.MARKER( 16:9)
SAFETY
2.→SAFETY AREA
80%
3.→ASPECT
4:3
4.→AREA IN ASPECT
80%
5.MARKER( 4:3)
SAFETY
6.→SAFETY AREA
80%
7.→ASPECT
16:9
8.ASP.MARKER MODE
MRK+SHD
9.→SHADOW LEVEL
40%
10.CENTER MARKER
OFF
11.MARKER LEVEL
80%
12.MARKER COLOR
□
13.USER MARKER
ON
14.→SETTING
EXECUTE
SET→ EXIT→
ENT
E S C
ENT
③ Setting the individual markers
<SETTING OF USER MARKER>
PAGE1
NO. COL SW DATA(X Y)
MK1
■ ON S: 0300 0250
E: 1200 0500
MK2
□ ON S:---- ----
E:---- ----
MK3
□ ON S:---- ----
E:---- ----
MK4
□ ON S:---- ----
E:---- ----
MK5
□ ON S:---- ----
E:---- ----
↓(NEXT PAGE)
SET→ EXIT→
ENT
E S C
ENT
④ Setting the modified size
<SETTING OF USER MARKER>
PAGE1
NO. COL SW DATA(X Y)
MK1
□ ON S: 0300 0250
E: 1200 0500
MK2
□ ON S:---- ----
E:---- ----
MK3
□ ON S:---- ----
E:---- ----
MK4
□ ON S:---- ----
E:---- ----
MK5
□ ON S:---- ----
E:---- ----
↓(NEXT PAGE)
SET→ EXIT→
E S C
ENT
(Hold down)
ENT
Hold down the
switch (or the right-hand button
on the mouse), and the data will be initialized (ー).
X axis
START POINT ( X:0300 Y:0250)
END POINT ( X:1200 Y:0500)
Y axis
Set USER
MARKER to ON.
Move the cursor
to the start
point.
START POINT ( X:0250 Y:0200)
END POINT ( X:1200 Y:0500)
Press ENT now.
START POINT ( X:0250 Y:0200)
END POINT ( X:1200 Y:0500)
Set the color
and ON/OFF
display for
individual
markers.
START POINT ( X:0250 Y:0200)
END POINT ( X:1850 Y:0800)
▼
The menu screen in
Step ③ reappears and
the new settings are
displayed at the X-Y
coordinate.
⑤
⑤ Setting a new start point
⑥ Modifying the start point
ENT
⑦ Modifying the end point
ENT
⑧ Shifting the end point
ENT
⑨ Saving the end point
- -
29
The start-point
X-Y coordinate
starts blinking.
The magenta-
colored cursor
appears at the
start point.
*If the end point
is positioned
above or to the
left of the start
point, the cursor
display position
depends on the
registered data.
▲
The shifted X-Y
coordinate is
displayed.
The end-point
X-Y coordinate
starts blinking.
The magenta-
colored cursor
appears at the
end point.
Move the cursor
to the end point.
Take the
procedure to
set a new start
point.
ESC
The cursor
moves to the
start point.