Replacing The Ttr Supply Hub And Adjusting Plate - Intermec 3600 Maintenance Manual

Bar code label printer
Hide thumbs Also See for 3600:
Table of Contents

Advertisement

3600 Printer Maintenance Manual

Replacing the TTR Supply Hub and Adjusting Plate

To replace the TTR supply hub, the TTR supply hub adjusting plate, or both
parts, you will need some or all of the following parts and tools:
To remove the TTR supply hub and TTR supply hub adjusting plate
1. Switch off the printer power and remove the power cord.
2. Remove the media cover, the electronics cover, and the front bezel cover
3. Raise the printhead. Remove media and ribbon if loaded.
4. Remove the two retaining snap rings and thin washer from the electronics
5. Pull the TTR supply hub away from the printer and remove the TTR
6. You can replace the TTR supply hub and TTR supply hub adjusting plate
5-20
TTR supply hub, Intermec Part No. 061562-004
TTR supply hub adjusting plate, Intermec Part No. 062603-001
Retaining snap rings, Intermec Part No. 501410
Ribbon supply hub alignment tool, Intermec Part No. T43149
ESD grounding strap
Snap ring pliers
#1 and #2 Phillips screwdriver
(refer to "Replacing the Bezel PCB" earlier in this chapter).
side of the TTR supply hub shaft as shown on the next page. Retain the
washer. Discard the old snap rings.
supply clutch/encoder assembly. Retain the TTR supply clutch/encoder
assembly (this assembly is not a spare part), the nylon washer, and the
thick steel washer.
now.