Intermec 3600 Maintenance Manual page 78

Bar code label printer
Hide thumbs Also See for 3600:
Table of Contents

Advertisement

3600 Printer Maintenance Manual
Printer Errors (continued)
Error Code
Problem
32
Non-immediate command or data
received after buffer full.
33
Invalid field delimiters.
34
Invalid escape command.
35
Invalid data shift command.
36
Invalid or undefined format
number.
37
Insufficient room in RAM to print
format.
38
Invalid or undefined field number.
41
Syntax error for program
commands.
42
Insufficient room in RAM to store
format.
43
Too many fields in label format.
46
Undefined statement.
52
Invalid UDC/UDF bitmap cell
height/width or intercharacter
space.
53
Insufficient room in RAM to store
UDC or UDF.
54
Invalid UDC command syntax.
4-8
Solution
Allow the printer to empty the buffer contents before
sending commands or data.
Check for all pairs of field delimiters, and make sure both
are numeric or both are alphanumeric.
Correct the escape command syntax.
Correct the shift command syntax.
Verify that the format numbers are between 0 and 19.
Reduce the number of data fields in the format.
Verify the field number in the label format.
Check the program command for proper syntax.
Empty the buffer contents. If the format still does not fit,
delete some fields or other data from the format. You may
have to remove or reduce the UDCs, formats, or fonts if
necessary.
Note: Entering <ESC>m tells the host how much memory is
installed and how much is available.
You can use up to 200 fields in a format and each field can
use up to 250 characters. Reduce field size or delete some
fields.
Check the statement syntax.
Verify that cell heights and widths are between 1 and 599,
and that the intercharacter space is between 0 and 199.
Remove or reduce formats, fonts, or UDCs.
Correct the UDC command syntax.

Advertisement