3600 Printer Maintenance Manual

Replacing the Power Switch/Circuit Breaker

To replace the power switch and circuit breaker assembly, you will need the
following parts and tools:
Note: The 220-volt printer uses a 1 amp power switch/circuit breaker and the 115-volt
printer uses a 2 amp power switch/circuit breaker.
To replace the power switch/circuit breaker
1. Switch off the printer power and remove the power cord.
2. Remove the media cover and the electronics cover.
3. Disconnect the two leads with push-on connectors attached to the power
5-32
AC power switch/circuit breaker, Intermec Part No. 501273-001 (2A) or
AC power switch/circuit breaker, Intermec Part No. 501273-002 (1A)
ESD grounding strap
Needlenose pliers
#2 Phillips screwdriver
switch.
Rear
panel
Tabs
Power switch/
circuit breaker
Transformer lead
AC power plug lead
3600M.063