Yamaha WR250F(T) Owner's Service Manual page 309

Table of Contents

Advertisement

Charging method using a constant voltage charger
YES
Charge the battery until the charging
voltage reaches 15 V.
Leave the battery unused for more than 30
minutes before measuring its open-circuit
voltage.
12.8 V → Charging is complete.
12.0 ~ 12.7 V → Recharging is required.
Under 12.0 V → Replace the battery.
Constant amperage chargers
are not suitable for charging
MF batteries.
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery
and start charging.
Is the amperage higher
than the standard charg-
ing amperage written on
the battery?
NOTE:
Set the charging time to a maxi-
mum of 20 hours.
CAUTION:
ELECTRICAL
This type of battery charger cannot
charge an MF battery. A variable
voltage charger is recommended.
Voltmeter
3 - 118
INSP
ADJ
NOTE:
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
NO
Charger
Ammeter

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wr250f

Table of Contents