S-104-100

CLAMPING

Alignment of Clamp Plates to Bedplate

1. Make sure the machine is in the home position.
2. Install clamp plates A, making sure that the clamp plates are parallel to the bedplate on both sides. If
they are not, perform steps 3 through 5.
3. Loosen screw B on outstop C, and screw D on instop E.
4. Manually push the right clamp towards the side of the bedplate. To adjust, loosen post F, slide it to the
right or left as necessary. Once the adjustment has been made, re-tighten post F.
5. Repeat steps 3 and 4 for the other clamp.
Revised 09/2004