S-104-100
CLAMPING
Adjusting the Clamp Pressure
The clamp foot pressure has been factory set for medium / heavy weight materials. Additional pressure
may be required for light weight materials. To adjust, perform the following steps:
1. Loosen nut A, B and turn adjustment screw C up or down (up increases clamp pressure; down
decreases clamp pressure) as necessary.
2. The correct amount of pressure is obtained when the material is held firmly by the clamp foot. Once
this has been achieved, re-tighten nuts A and B.
CAUTION: Avoid using excessive pressure.