Setting The Spread Of The Clamp Plates - AMF SERIES S104-130 Parts And Service Manual

S104-130 series eyelet buttonhole machine
Table of Contents

Advertisement

S-104-100
CLAMPING

Setting the Spread of the Clamp Plates

The distance of the spread will be determined by the sewing application. The standard clearance between
the edge of clamp plate A and outstop C is 0.76 mm (.030"). To adjust, perform the following steps:
1. Turn the left hand crank so that the clamp rolls are not resting on the spreader block. Place the feeler
gauge between the edge of clamp plate A and outstop C. Slide the clamp plate towards the outstop until it
can no longer move. Holding the clamp plate against the feeler gauge using a screwdriver, slide instop E
outward. Once the instop is over as far as it will go, tighten screw D. Once the clearance has been ob-
tained, remove the feeler gauge.
2. Repeat step 1 to obtain clearance between the other clamp plate and the outstop.
Revised 09/2004
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
1-61
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606