NOTICE!
Enter command [9 5 9] [#] to exit if the setting does not need to be saved.
3.3.2

Programming with the ICP-EZPK Programming key

The ICP-EZPK Programming key allows you to save or copy programming information from
your control panel. After saving information in the programming key, you can easily program
other AMAX panel 2000 / AMAX panel 2000 EN with the same programming data. You can also
use the programming key to back up existing information.
If you have a new programming key, enter installer's programming mode, program the system
as required, and connect the programming key to the control panel.
To connect the programming key:
Locate the socket labeled PROGRAMMING KEY at the top of the printed circuit board (PCB).
Observe the triangular markings on the PCB and align them with the markings on the
programming key.
For example: to copy data from the control panel to the programming key:
1.
2.
3.
4.
CAUTION!
If you do not enter installer's programming mode first, which connects the blank ICP-EZPK
Programming key to the control panel, no data can be uploaded /downloaded.
An unknown error may be caused if the installer's programming mode is not exited before
removing the programming key.
3.3.3

Installer's Programming Command

There are six commands that you can use in installer's programming mode. To issue the
command, enter the command number and press [#].(CMD 959-999). Refer to
Section 6 System Functions, page 39
3.3.4

Default the control panel with the hardware

If the installer code is lost, the default pads on PCB can be used to default the control panel.
1.
2.
3.
4.
5.
F.01U.241.127 | V4 | 2011.12
Enter the installer code (the default is 1234) + (958) and press [#] to enter into
installer's programming mode.
Enter [9 6 2 #].
Refer to Section 6.23 Command 962 – Copy the control panel memory to the programming
key, page 46.
Enter [9 6 0 #] to exit from installer's programming mode.
The system resets and returns to the disarmed state. And the programming key becomes
your standard data pattern for future control panel programming.
Disconnect the AC MAINS supply and the backup battery from the control panel.
Short the default pads. The default pads is located on the right top of the PCB next to the
PROGRAMMING KEY socket.
Reconnect the power supply to the control panel.
If the LED on the control panel PCS flashes fast, release the default pads about 5
seconds later.
The control panel is successfully defaulted to the default Installer und User Code, other
parameters are not defaulted.