ICP-CC488 | User's Guide | 1.
1.

Introduction

Congratulations on selecting the ICP-CC488 Control
Panel to protect you and your property. To obtain
the most from your unit, take time to read through
this manual and familiarize yourself with the
numerous outstanding operating features of this
system. In all aspects of planning, engineering,
styling, operation, convenience, and adaptability, we
have sought to anticipate your every possible
requirement.
Programming simplicity and speed were some of the
major considerations and we believe that our
objectives in this area were more than satisfied.
This manual explains all aspects of operating the
control panel. All system parameters and options are
detailed; however, suitability is left up to the
individual. Every system can be tailored to meet all
requirements quickly and easily.
2.

Specifications

Table 1:
Specifications
Temperature Range
Humidity
Power Source
Stand-By Current
Current Draw in
Alarm Condition
Current Draw in
Alarm Condition with

Codepad

Back-Up Battery
Dimensions (Case,
packed in carton)
Weight
Supplier Code
New Zealand
Telepermit
Test the sirens, strobe, and zones at
weekly intervals. Refer to Section 14.
Testing for further information.
Bosch Security Systems, Inc. | 12/08 | F01U089456-02
Introduction
o
o
0
C to +45
C
o
o
(+32
F to +113
F)
10% to 95%
TF008 Plug Pack –
240 V/18 VAC @ 1.3 A
65 mA
115 mA
105 mA
6 Ah/12 VDC Rechargeable
Sealed Lead Acid Battery
306 mm x 262 mm x 84 mm
(12.05 in. x 10.31 in. x 3.31 in.)
2.5 kg
(5.51 lb.)
N771
PTC 211/98/084
ICP-CC488 –
PTC 211/98/083
3.

Codepad Indicators

Figure 1:
ICP-CP508W Eight Zone LED
Codepad
Figure 2:
ICP-CP508LW Eight Zone LCD
Codepad
Figure 3:
ICP-CP516 Sixteen Zone LED
Codepad
EN | 5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICP-CC488 and is the answer not in the manual?

Questions and answers

Tirrel Graham
January 17, 2025

I have had a 24hr blackout and my screen is blank

User image 6789c09e5421f
1 comments:
Mr. Anderson
May 14, 2025

If your Bosch ICP-CC488 screen is blank after a 24-hour blackout, you must reset the system time, as it resets every time the system is powered down. Use the 24-hour HHMM format (e.g., 10:30 PM as 2230).

This answer is automatically generated

marilyn
February 1, 2025

after recent power outage due to thunder storms in the area, my panel is beeping occasionally. what is the reset button please i have the user guide, which pages refers,

1 comments:
Mr. Anderson
May 14, 2025

The reset button (default button) for the Bosch ICP-CC488 control panel is located at the top of the PCB next to the PROGRAMMING KEY socket.

This answer is automatically generated

John Hammond
March 28, 2025

My home alarm keeps going off once the alarm has been set even though there's no one in the sensor area. I've reprogrammed the setting codes, but that's not made any difference?

1 comments:
Mr. Anderson
March 28, 2025

The Bosch ICP-CC488 home alarm may keep going off after being set, even with no movement in the sensor area, because a zone was unsealed at the end of Exit Time and was automatically isolated. If that zone (e.g., an open window) is later closed and then reopened, it becomes active and triggers an alarm. This can happen if forced arming is enabled and an unsealed zone is not properly sealed or manually isolated before arming.

This answer is automatically generated

Subscribe to Our Youtube Channel

Table of Contents

Save PDF