Smartnode 2400 Line Power Module Installation - Patton SmartNode 1000 Series Getting Started Manual

Smartnode 1000 & 2000 series voip media gateways
Table of Contents

Advertisement

8 • Line power module installation

SmartNode 2400 line power module installation

The 40V line power module is mounted inside the SmartNode 2400, next to the existing 12V power supply.
You should not move the 12V power supply module from its installed location (see
supply location).
Figure 84. Internal 40V line power module and 12V power supply module locations in SmartNode 2400
Note
130
Do not install a 48V line power module into the SmartNode 2400!
The 12V and the 40V line power modules are very similar in appear-
ance. The 40V module is labeled ZWS30-36 on the large electrolytic
capacitor (see
figure
84).
Connecting the 40V line power supply to the 12V socket instead of the 40V
socket may result in permanent damage to the main board.
SmartNode 1000 and 2000 Series Getting Started Guide
Internal PM-48V-INT or PM-40V-INT line power module installation
figure 84
for 12V power