Testing A Dual Band Mobile With Manual Test (Synchronous Mode) - Agilent Technologies E6392B User Manual

Gsm ms test set
Table of Contents

Advertisement

Using Functions

Testing a Dual Band Mobile with MANUAL TEST (Synchronous mode)

Testing a Dual Band Mobile with MANUAL TEST (Synchronous
mode)
The following procedure explains a test on a dual band (GSM900 and DCS1800)
mobile phone with the MANUAL TEST synchronous mode.
Step 1. Turn the Test Set on and wait for its selftest routine to finish.
Step 2. Refer to
starting the test.
Step 3. Press the MANUAL TEST softkey in the initial screen to obtain the MANUAL
TEST: Stand-by screen shown below.
Step 4. If the Test Set is equipped with Option 002, make sure that Sync is selected
(underlined) in the Mode Sync/Async softkey. (Note that this softkey is not
available for the Test Set without Option 002.)
Step 5. Rotate the CURSOR CONTROL knob and see how the circular cursor changes its
position.
At one field, press the CURSOR CONTROL knob, then rotate it. You see that field
changes its values. Press the CURSOR CONTROL knob to enter that value.
34
"Preparation for Each Test" on page 22
for the procedures required before
Step 6
Chapter 2

Advertisement

Table of Contents