Agilent Technologies E6392B User Manual page 158

Gsm ms test set
Table of Contents

Advertisement

The following test items need to be set to either "Run" to execute a Pass/Fail test or
to "---" (skip) not to execute a Pass/Fail test, for each channel or dc power,
respectively:
Peak TX Power
Burst Timing
Power Ramp
Phase Error
Frequency Error
Sensitivity
RX Quality
RX Level
DC Current
When TCH is set in the Variable field and the all of test items are set to skip for
one TCH, only the handover capability can be tested for that TCH.
Chapter 3
Test Item
Defines whether to run or skip the Peak TX Power test for the
High, Mid, and Low levels. The MS power class and the power
control levels for the High, Mid, and Low levels are defined in
the Test Setup: Test Condition screen.
Defines whether to run or skip the Burst Timing test. In the
GPRS mode, this will be substituted by Power vs Time.
Defines whether to run or skip the Power Ramp test. In the
GPRS mode, this will be substituted by Power vs Time.
Defines whether to run or skip the Phase Error test.
Defines whether to run or skip the Frequency Error test.
Defines whether to run or skip the Sensitivity test in BER and
FER. In the GPRS mode, BLER will substitute BER and FER.
The BS level and the number of test frames are defined in the
Test Setup: Test Condition screen.
Defines whether to run or skip the RX Quality test. In the GPRS
mode, this can not be measured.
Defines whether to run or skip the RX Level test. In the GPRS
mode, this can not be measured.
Defines whether to run or skip the DC Current test at Camp On
and Talk steps.
Screen Reference
CONFIGURATION
Description
157