Screen Fields
The following input fields of the parameters need to be set for a new test sequence
for executing AUTOMATIC TEST.
Radio Standard
Multi Band
BCCH
DC Power
Chapter 3
Input Field
Selects either GSM900, E-GSM, DCS1800, or PCS1900.
Selects another band in addition to one in Radio Standard for
testing dual band mobile phones. The allowable combinations of
radio standards are as follows:
Radio Standard:
GSM900
E-GSM
DCS1800
PCS1900
a
Specifies the broadcast control channel. The frequency
corresponding to the channel accompanies. The allowable range is
as follows:
GSM900: 1 to 124
E-GSM: 0 to 124, and 975 to 1023
DCS1800: 512 to 885
PCS1900: 512 to 810
Selects a supply mode. The choices are Auto, On, and Off as
follows:
o Auto: Supplies dc voltage to the mobile only during a test
cycle.
o On: Always supplies dc voltage to the mobile.
b
o Off
: Disables to supply dc voltage to the mobile. If Off
is selected, the Variable field is automatically set to TCH.
Accepts a dc voltage value ranging from 3.0 to 11.0 V in 0.1 V
steps. This value is used among the AUTOMATIC TEST,
MANUAL TEST, SPECTRUM MONITOR, and SIGNAL
GENERATOR modes in common.
Screen Reference
CONFIGURATION
Description
Multi Band:
OFF, DCS1800
OFF, DCS1800
OFF, GSM900, E-GSM
OFF