Software
installation. This will install the Intel
(Figure
Figure 18.
Selecting the SCSI Adapter
Note:
Slipstreaming the Intel
SP3 installer will not work.
7. During the installation, the message box below may appear:
At this time, any low/full speed USB devices (for example the keyboard and mouse)
that are connected to USB port 1 (Device2:Function0), USB port 3
(Device2:Function1) and USB Port 5 (Device2:Function2) will not function for a
brief period during installation. This may appear due to an OHCI driver issue for
USB Host controller #1 (Device 2: Function 0-2). These USB ports will resume
working once you can dismiss the above message box by clicking Yes.
indicates the internal USB port connections.
The proposed workarounds for this issue are:
— For a customer design that has PS2 ports, please use a PS2 mouse and
keyboard to facilitate the installation.
— For a customer design that has USB port 0/2/4 (USB Host controller #0 Device
8:Function 0-2), use those ports for the USB mouse and keyboard connection
to facilitate the installation.
January 2012
Document Number: 324213-002
18).
®
PCH EG20T SATA AHCI controller driver onto the Windows XP
®
Intel
Atom™ Processor E660 with Intel
®
PCH EG20T SATA AHCI controller driver
®
Platform Controller Hub EG20T Development Kit
Figure 19
User Manual