Configure the raw device according to the manual of the application
used for raw access to the replacement hard disk. That application
was stopped before the replacement. After completing the
configuration, restart the application.
4.2.4.Replacement procedure (for hard disk
failures causing non-responsiveness)
If HDD recovery using an HDD driver is not possible because a hard disk failure
caused the relevant HDD to hang, replace the hard disk by using the following
procedure.
1.
If the system is non-responsive because of a hard disk failure, the
following message detected by SVagent appears and the Fault LED of the
hard disk goes on:
For RHEL5:
Serverview: E 14134 IOB#n-HDD#n scsi:%h:%c:%i:%l \
Device error (offlined) vendor=xxxxxxxx \
model=xxxxxxxx serial-no=xxxxxxxxxx \
SCSI number: %h=host number, %c=channel number, \
%i=id number, %l=lun number
The \ at the end of a line indicates that there is no line feed.
SVmco User Guidel
146