SVmco User Guide
%m: (Example) MAP3367NC
Corrective action:
If you were working on a DAT by using a command such as dd, confirm that the
specified parameters are correct. If you are sure that there is no mistake in the
work, a hardware failure occurred. Replace the drive.
Severity:
Warning
Action:
(R/M/T/S)
14025
st:st[0-9]* Device or Software error (Incorrect block size) vendor=%v
model=%m
Meaning:
A device or application error occurred. The block size or the size specified for
read is invalid for a fixed-length device.
%v: (Example) FUJITSU
%m: (Example) MAP3367NC
Corrective action:
Check the block size for read. If there is no problem with the block size, replace
the drive.
Severity: