MPD:\Device\ScsiPort%3 Adapter or FC-Network error (Some of the paths could
not be detected) vendor-id=10DF device-id=%d revision=%r
Meaning:
Multipath operation could not be started for the device indicated by
\Device\ScsiPortP(PathId=B, TargetId=T) because of an unplugged cable or device
failure.
%3: Scsi number
%d: (Example) F980
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the device indicated by \Device\ScsiPortP(PathId=B, TargetId=T).
If the operating system is Windows Server 2003, identify the faulty part according to the
"Procedure for Identifying the Faulty Fibre Channel (FC) Adapter
Severity:
Error
Action:
(R/M/T/S)
25004
MPD:\Device\ScsiPort%3 Adapter or FC-Network error (device was
removed) vendor-id=10DF device-id=%d revision=%r
Meaning:
\Device\ScsiPortP(PathId=B, TargetId=T) became unavailable because of an unplugged
cable or device failure.
SVmco User Guidel
Part."