4.3.2.Hard Disk Preventive Replacement - Fujitsu PRIMEQUEST 1000 Series User Manual

Serverview mission critical option
Hide thumbs Also See for PRIMEQUEST 1000 Series:
Table of Contents

Advertisement

SVmco User Guide
6.
After replacing the hard disk, confirm that hard disk replacement was
completed properly, by using the following steps depending on whether the
disk is a spare disk.
If not set as a spare disk:
o
ServerView RAID Manager automatically performs a rebuild. Then,
the Alarm LED of the hard disk starts blinking.
Wait until the rebuild is complete in the ServerView RAID Manager
window. Confirm that [Status] for the hard disk is [Operational].
If set as a spare disk:
o
The replacement hard disk automatically becomes a spare disk.
Then, the Alarm LED of the hard disk goes out.
In the [ServerView RAID Manager] window, confirm that [Status] for
the hard disk is [Global Hot Spare] or [Dedicated Hot Spare]. After
the rebuild is complete, a copyback operation may be performed.
7.
Exit ServerView RAID Manager.
4.3.2.Hard disk preventive replacement
This section describes the workflow for preventive replacement of a hard disk S.M.A.R.T
predicted to fail.
For the RAID 0 configuration (cold-partition replacement)
To replace a hard disk in the RAID 0 configuration, apply cold-partition
maintenance.
The workflow is described below.
151