Corrective action:
Replace the offline HDD. Perform a rebuild. For multi-dead, take corrective
action according to the multi-dead recovery procedure.
Severity:
Warning
Action:
(R/M/T/S)
28567
SV RAID:%2 Adapter error (SAS port lost link) vendor-id=1000/1734 device-
id=%d revision=%r
Meaning:
The SAS link was terminated.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Review the system connection configuration. If the error recurs, replace the
possibly faulty component of the SAS interface system.
Severity:
Error
Action:
SVmco User Guidel