Meaning:
An abnormal battery temperature was detected.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Check the fan status in ServerView. If a fan failure occurred, take corrective
action for the target unit.
If no fan failure occurred, recheck the environment temperature. If the error
recurs after you rechecked the environment temperature, replace the BBU.
Severity:
Error
Action:
(R/M/T/S)
18503
SV RAID:%2 Adapter error (BBU voltage out of range) vendor-id=1000/1734
device-id=%d revision=%r
Meaning:
An abnormal battery voltage was detected.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
SVmco User Guidel