2–Event Messages

Informative Events

Informative Events
Informative events are events that occur in the normal activities of a fabric. The
following lists the event ID and text of the message along with an explanation of
the message.
(I) (8200.0001) (mserver) (Hotreset is not permitted at this time, try again later)
Meaning:
(I) (8200.0002) (mserver) (Port: port_number) (Rejecting request from address FC_address,
inband management is disabled on port port_number)
Meaning:
(I) (8200.0100) (mserver) (Cannot map number_of_characters characters to Switch
Symbolic Name (max number_of_characters))
Meaning:
(I) (8200.0101) (mserver) (Cannot map non-printable characters to Switch Symbolic Name)
Meaning:
(I) (8200.0200) (mserver) (Rejecting request (GZM) for zone zone_name containing
unsupported alias member(s)
Meaning:
(I) (8200.0201) (mserver) (Rejecting request command:command)
Meaning:
2-72
The switch was busy at the time of the attempted hot reset. Try the
hot reset again later.
A Management Server command was received on a port that is
configured to refuse inband management requests.
The RIELN management server command was processed, and the
Interconnect Element Logical Name was registered. However, the
registered name is of greater length than the maximum length
allowed for the Switch Symbolic Name, so therefore the Switch
Symbolic Name was not changed to match the registered name.
The RIELN management server command was processed, and the
Interconnect Element Logical Name was registered. However, the
registered name contains unprintable characters. These characters
are not allowed for the switch symbolic name, therefore the switch
symbolic name was not changed to match the registered name.
The fabric zone server command GZM (Get Zone Member) was
rejected because the requested zone member was an alias that is
not defined in Fibre Channel General Services-3 (FC-GS-3).
A fabric zone server command was rejected for the reason detailed
in the message. This can be caused by two users attempting to
configure the switch or zoning database at the same time. Contact
your authorized maintenance provider if the reason for the failure is
not clear.