(A1003.0010) (Segmenting, zoneset zone_set_name not defined)
Meaning:
Action:
(A1003.0011) (Segmenting, zoneset zone_set_name already active)
Meaning:
Action:
(A1003.0012) (Segmenting, zoneset zone_set_name merge conflict)
Meaning:
Action:
(A1003.0013) (Segmenting, zone zone_name merge conflict)
Meaning:
Action:
(A1003.0014) (Segmenting, alias alias_name merge conflict)
Meaning:
Action:
(A1003.0015) (Zoneset Activation received from switch with domain domain_ID failed,
unknown zoneset zone_set_name)
Meaning:
Action:
59060-07 D
In non-interop mode, there is a conflict in the zoning configuration,
causing the Inter-Switch Link (ISL) to isolate. The zone set is not
found within the local zoning data base while interop mode is
disabled.
Contact your authorized maintenance provider.
In non-interop mode, there is a conflict in the zoning configuration,
causing the Inter-Switch Link (ISL) to isolate. A switch tried to
activate a zone set that is already active while interop mode is
disabled.
Contact your authorized maintenance provider.
In non-interop mode, there is a conflict in the zoning configuration,
causing the Inter-Switch Link (ISL) to isolate. After a zone merge
with interop mode disabled, two zone sets were discovered in the
local zoning database with the same name, but different
membership.
Contact your authorized maintenance provider.
In non-interop mode, there is a conflict in the zoning configuration,
causing the Inter-Switch Link (ISL) to isolate. After a zone merge
with interop mode disabled, two zone were discovered in the local
zoning database with the same name, but different membership.
Contact your authorized maintenance provider.
There is a conflict in the zoning configuration causing the
Inter-Switch Link (ISL) to isolate. Two aliases with the same name
but different membership were discovered in the local zoning
database.
Reconcile the active zone sets so that the two aliases have
identical membership.
A zone set activation received from the named switch failed
because the zone set was not in the zoning database.
Examine the named switch to verify that the zoning database is
correct.