(A1003.0021) (Failing remote zoning configuration, Zoneset is empty)
Meaning:
Action:
(A1003.0022) (Unable to update database with newly activated information, Zoning Save in
Progress)
Meaning:
Action:
(A1003.0023) (Fabric Busy Zoneset operation failed)
Meaning:
Action:
(A1003.0024) (Request already in progress (internal lock held))
Meaning:
Action:
(A1003.0025) (Error reading security set.)
Meaning:
Action:
(A1003.0028) (SFC failure received from remote switch with domain domain_ID)
Meaning:
Action:
(A1003.0029) (No response received from switch with domain ID domain_ID)
Meaning:
Action:
59060-07 D
An empty zone set was included as part of a zone merge and was
rejected.
Modify the zoning database on the remote switch to remove or
correct the empty zone set.
Modifications were being made to the security or zoning database
while a security set or zone set was being activated or deactivated
from a remote switch.
Try the activation or deactivation again later.
The activation or deactivation of a zone set failed because the
fabric is currently busy.
Try the activation or deactivation again later.
A fabric operation is currently in progress.
Wait and try again.
There was a problem handling the activate direct management
server command. The format of the command was not standard.
Check the security configuration.
The remote switch given by domain_ID rejected the Staged Fabric
Configuration (SFC) message, so the SFC request has failed.
Check the status of the remote switch at the given domain ID.
There could be an issue with the security configuration or the
zoning configuration.
The remote switch given by domain_ID did not reply to an Acquire
Change Authorization (ACA) message, so the ACA request has
failed.
Check the status of the remote switch at the given domain ID.
There could be an issue with the security configuration or the
zoning configuration.