Qlogic 3000 Series Reference Manual page 42

Fibre channel event message fibre channel switch
Hide thumbs Also See for 3000 Series:

Advertisement

2–Event Messages
Alarm Events
(A1005.0066) (Switch is not fault-tolerant. Fault Tolerant license is installed, but secondary
CPU is faulted)
Meaning:
Action:
(A1005.0067) (HyperStack(tm) license installed, but only 1 CPU blade installed - alarm
status)
Meaning:
Action:
(A1005.0068) (Primary blade seating is questionable)
Meaning:
Action:
(A1005.0069) (Primary blade seating was resolved)
Meaning:
Action:
(A1005.006A) (User account account_name has expired)
Meaning:
Action:
(A1005.006B) (Temperature too high, turning off lasers)
Meaning:
Action:
(A1005.006C) (3.3V out of spec, turning off lasers)
Meaning:
Action:
2-28
The QLogic 9000 switch is not fault tolerant because of a fault on
the secondary CPU blade.
Replace the secondary CPU blade.
A QLogic 9000 switch that is licensed for HyperStacking must have
two CPU blades to make use of the HyperStack feature. If only one
CPU blade is installed, this alarm message is issued with alarm
status ALARM SET. When the second CPU blade is installed, the
alarm message is reissued with alarm status ALARM CLEAR.
If the alarm status is ALARM SET, install the second CPU blade.
The QLogic 9000 primary CPU blade is not fully installed.
Reseat the primary CPU blade.
The QLogic 9000 primary CPU blade seating problem has been
corrected.
None
The named user account has exceeded its expiration date.
Review the user account and make the necessary corrections.
The switch has overheated and the Fibre Channel port lasers have
been turned off.
Power down the switch, correct the conditions that caused the
switch to overheat, and power up the switch.
Fibre Channel switch ports are receiving incorrect voltages. Lasers
have been turned off.
Contact your authorized maintenance provider.