(A1007.0002) (Security: Remote Switch with WorldWide Name (WWN) wwn configured for
chap, no chap configured for local switch. 2-way Authentication Failure)
Meaning:
Action:
(A1007.0005) (Security: Authentication request was rejected by port.)
Meaning:
Action:
(A1007.0006) (Security: Could not validate Authentication Response from port_number,
payload seems to be incorrect.)
Meaning:
Action:
(A1007.0007) (Security: Fabric Binding (ESA) not supported on remote switch and Fabric
Binding is enabled, failing security checks)
Meaning:
Action:
(A1007.0008) (Security: ESA Response failure, failing security checks)
Meaning:
Action:
(A1007.0009) (Security checks EFMD response failure, failing security check.)
Meaning:
Action:
59060-07 D
The device WWN is either not configured in the security database,
or it is not configured for Challenge Handshake Authentication
Protocol (CHAP).
Add the device WWN to the active security set if it missing, or
modify the group to allow for CHAP authentication with the other
devices.
Indicates that a remote switch rejected a security authentication
attempt. The port will isolate.
Checks the security configuration on the remote switch to
determine the problem.
The format of the payload of the response frame does not match
what was expected.
Check for errors on the remote side of the link. Check the
transceiver and cable. Update firmware on remote switch.
Either fabric binding is not enabled on the remote switch or the
remote switch does not support security at all.
Check the security configuration on the remote switch.
A failure was received during processing of the ESA received
frame. Either the payload did not match the standard layout or the
payload status indicated a reject.
Check for errors on the remote side of the link. Check the
transceiver and cable. Update firmware on the remote switch.
A remote switch rejected a Exchange Fabric Membership Data
(EFMD) frame. The port will be isolated.
Check remote switch for the reason that the EFMD frame was
rejected. It is possible that the FabricBindingEnabled parameter is
different on the two switches.
2–Event Messages
Alarm Events
2-37