Download Print this page

Qlogic 3000 Series Reference Manual page 39

Fibre channel event message fibre channel switch
Hide thumbs Also See for 3000 Series:

Advertisement

(A1005.004E) (Attempts to login backend switch fail because backend switch does not
support NPIV.)
Meaning:
Action:
(A1005.004F) (Media device sensor is value units. Transitioning from state to state)
Meaning:
Action:
(A1005.0050) (Media device device_name is value units. Transitioning from state to state)
Meaning:
Action:
(A1005.0051) (Canceling config edit mode as a result of a CPU switchover)
Meaning:
Action:
(A1005.0052) (Canceling IP ping as a result of a CPU switchover)
Meaning:
Action:
(A1005.0053) (Canceling FC ping as a result of a CPU switchover)
Meaning:
Action:
(A1005.0054) (Canceling FC Trace Route as a result of a CPU switchover)
Meaning:
Action:
59060-07 D
The backend fabric switch does not support N_Port ID
Virtualization (NPIV), which in turn brings down the TF_Port.
Ensure that the backend fabric switch supports NPIV.
The specified sensor (temperature, voltage, TxBias, TxPower,
RxPower) has set a fault. The sensor reports its value (°Celsius,
volts, milliAmps, milliWatts) and transition states (low alarm, low
warning, normal, high warning, high alarm).
For the temperature sensor transitioning from low alarm to high
alarm, cool the system. For all other sensors transitioning from low
alarm to high alarm, replace the media.
The specified sensor (temperature, voltage, TxBias, TxPower,
RxPower) has cleared an existing fault. The sensor reports its
value (°Celsius, volts, milliAmps, milliWatts) and transition states
(low alarm, low warning, normal, high warning, high alarm).
None
A CPU blade switchover occurred while a Config Edit session was
open. The Config Edit session was canceled.
Reopen the Config Edit session.
A CPU blade switchover occurred while an Ethernet ping was in
progress. The Ethernet ping was canceled.
Retry the Ping command.
A CPU blade switchover occurred while an Fibre Channel ping was
in progress. The Fibre Channel ping was canceled.
Retry the Fcping command.
A CPU blade switchover occurred while an Fibre Channel trace
route was in progress. The trace route was canceled.
Retry the Fctrace command.
2–Event Messages