Switchshow lines for FCoE ports should always be in short format.
If user selects authentication type as "all", in interop modes the default
authentication type is still FCAP between FOS switches.
Fabric watch is allows setting of the Traits and Alarm configuration
even when no alarms are available for all of the classes in WebTools.
The 'swFCPortTable' displays the port statistical data for the logical
port.
Encryption blade turns faulty 21 after firmwaredownload and reboot
of DC SAN Director.
Create 2 access-list with 170 rules in each ACL and apply on 2 ports.
Statistics is not updated for one of the ACL.
MAC access-group is not removed even after executing no mac access-
group in the interface mode.
In interop mode 2, with Default Zone enabled, the user can activate
only 2047 Zones per Zone Set.
Event for change in IDID state on neighboring switch not being posted
to log.
In connUnitLinkTable,for the attribute connUnitLinkConnIdY there is a
mismatch between the PID displayed on the CLI and browser.
Backport code to address various SNMP related issues.
User might observe a Name server related verify on console after
firmware download followed by power cycle on the 4/256 SAN Dir-
ector.
Using WebTools's HA tab, synchronize button and details button do
not work as expected.
Public/Private keys are not copied during HA failover.
Occasionally, after a firmwaredownload or an HA failover on a chassis
system, users will notice a message on standby CP console: "cannot
create symbolic link '/etc/localtime' to '/usr/share/zoneinfo/..."
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
.csv file related changes are
checked-in by the CLI gatekeeper. so
resolving this TR.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Slotpoweroff/slotpoweron the blade
or remove the blade and insert back.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Use "hasyncstart" from CLI.
Fixed in FOS 6.3.0
Workaround prior to code change:
Use SCP with passwords or if
password-less SCP is to be used,
generate a key pair for SSH outgoing
authentication from the switch or: The
workaround was to do the following:
hadisable sshutil delprivkey sshutil
delpubkeys haenable.
Fixed in FOS 6.3.0