Pending Merge: Repeatedly disconnect/reconnecting the ISL links
between the HP StorageWorks Encryption SAN Switch in the HA cluster
environment while rekey operations are in progress may cause data
miscompare.
Encryption group can't automatically recover after it is split into 2 dif-
ferent islands.
Firmwaredownload failed on HP StorageWorks DC SAN Director.
Pending Merge: Host throughput drops 75% when rekey is started.
All LUNs in a container are showing target offline.
After encountering a rare error condition, a switch/director may fail
to clear an interrupt, resulting in a persistently high CPU load.
SNMP v3 user configuration reverts back to defaults after HAfailover.
IFCC's when disabling trunks and having DPS enabled.
Reset factory default using the faceplate pinhole caused FFDC and
VCM shows "No Communication" to the switch
Pending Megre: During rekey operations, continuously disconnect/re-
connect the ISL links between 2 cluster nodes, causes one of the LUN
to hang at "LUN discovery" state.
Pending merge: Rekeying and toggling ISL to trigger HAC failover in
4 node dual fabric caused the DC Switch Encryption Blade in slot3 of
the DC SAN Director and Encryption SAN Switch fault: BKSW-1003]
HL_BES101, kSWD: Detected unexpected termination of: ''[4]CVLC.
DC SAN Director-upgrade from v6.1.1a to v6.2.0, hit FFDC, then
panic-detected termination of process pdmd:2676.
Pending Merge: Encryption SAN Switch Faulty during reboot -f test.
SNMPd core file filled up the root file system on the DC04 SAN Direct-
or.
Continuously disconnect/reconnecting the ISLs in the HA environment
causes one of the Encryption SAN Switches to go into faulty state.
Command "fddcfg –fabwideset" and other security commands fails
with RCS transaction error.
With tape pipelining active, the switch may return a good status without
sending data.
DC SAN Director ASIC parity errors, ICL CRC's and IFCC's on
overnight workload.
Host detecting IFCCs errors to CUP Port.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
CPs were not in sync when
downgrading to v6.1.1a. Did net
install on DC SAN Director to v6.1.1a
and upgrade to v6.2.0b.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
HP StorageWorks FOS 6.3.0b Release Notes