FICON XRC Emulation error handling OOO Status Frames.
HIL-1610 WARNING appeared on 8/40 switch units after power
cycle.
Temperature sensor reporting spurious solitary readings which leads
to the CRITICAL HIL-1502 message, without having first gone through
the HIL-1501 warning.
Unable to get F Ports(Trunk Ports) data.
On some of 2408 FCoE Converged Network switches, DIAGPOST is
failing due to loss of sync.
Processor rebooted - Software Fault:ASSERT when frame size received
is too big.
Need to support a command "clear logging" to clear all debug log
messages accumulated.
CLI output consistency and input validation issues around key lifespan
option of a LUN.
High Availability : User is able to change the "desired distance" for
long distance "L0".User should not be able to change the "Desired
distance", if the "Long distance" value is "L0". It should always be
"N/A" for L0.
After firmware upgrade, FC FastWrite traffic sometimes fails.
A few VERIFY are dump out on DC SAN Director and Multiprotocol
Router Blade EX port stuck without showing switch name of the edge
fabric switch etc during edge switch firmwareupgrade.
FMS mode should be blocked when a logical switch is in 10 bit ad-
dressing.
TI Zone activation failed when pushing from DCFM to fabric with
v6.2.0 and v6.1.2.
The drive is taken offline after container is failed back.
52
Fixed in FOS 6.3.0
Workaround prior to code change:
Option 1: Deactivate all paths that
utilize the same device ports and
reactivate at the same time. Option
2: Disable FICON XRC emulation.
Fixed in FOS 6.3.0
Workaround prior to code change:
Ignore the warning - it is innocuous
when seen right at boot up time. It
results from a solitary spurious sensor
reading that is below minimum.
Fixed in FOS 6.3.0
Workaround prior to code change:
Ignore isolated / spurious High
Temperature CRITICAL errors when
not preceeded by warnings.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Go to FOS mode and issue an
"errclear" command.
Fixed in FOS 6.3.0
Workaround prior to code change:
Input validation issues. Requires the
user to provide valid input.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0