Command "portcfgdefault " performed on an internal Fport will convert
that Fport into an NPort.
EE monitor counter is not incrementing after firmware upgrade to 6.2.0.
ISL monitor total transmit and number of destination domains monitored
counters show 0 when traffic is running thru this ISL.
SNMP: The swNs Table does not list all the name server entries.
Interopmode 2 - Value other than 0 or 1 in configdownload file will
enable default zone; I was expecting an error message.
IP monitor shows number of SCSI frames after deleting a SCSI filter
monitor and adding IP monitor on the same port.
Onboard Administrator used to manage 8Gb SAN Switch for
BladeSystem c-Class is not able to read the switchname.
Statsclear does not clear porterrshow statistic data for field "link fail "
on 6-port 10Gb/s ISL blade.
"Cyptocfg --show -tapepool -all -stat" returns "Operation failed:" the
first time it's issued but displays valid output when immediately re-is-
sued.
With virtual fabric enabled, when no EE is present, cryptocfg show
localEE returns "EE detection aborted: IPC Failure".
A LUN with encryption mode: cleartext and encryption format: Brcd
Native, fails to read DF_Compatible tape media.
After repeatedly deleting and adding partitions, creating a new parti-
tion resulted in an ASSERT at "file = .../bccb/lib/utils/register.c, line
= 115, user mode" and termination of ficud.
SR Request for IBM PMH 85437,000,738 - HK Monetary.
Unable to clear Port Name from screen " Edit CUP Port Connectivity
Configuration."
SNMP changes required to better support snmp mib.
Fixed in FOS 6.3.0
Workaround prior to code change:
When the system is working well,
save that configuration somewhere so
that it can be reapplied instead of
relying on portcfgdefault.
Fixed in FOS 6.3.0
Workaround prior to code change:
Delete and re-install EE Monitors.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Switch name can be displayed from
FOS CLI command - switchname.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Re-issue the CLI.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Configure the LUN with encryption
mode:encrypt & encryption
format:DF_Compatible and restore
the files from the tape media.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
HP StorageWorks FOS 6.3.0b Release Notes