HP StorageWorks 1606 - Extension SAN Switch Release Note page 63

Hp storageworks fos 6.3.0b release notes (5697-0360, april 2010)
Hide thumbs Also See for StorageWorks 1606 - Extension SAN Switch:
Table of Contents

Advertisement

If second FDISC comes in before the switch responds to the first FDISC
between the same pair of devices, the Access Gateway daemon
panics.
In WebTools, for Add operation in VLAN in CEE tab, all created data
is not added in the table.
FCAP works only in Non-VF mode or VF mode with Default Switch.
Unexpected software call traceback error messages are being dis-
played on the console.
DC SAN Director standby CP may reboot due to ASSERT - Failed ex-
pression: new_snode != NULL if the chassis have 6-port 10Gb FC ISL
blade.
When the Ethernet connectivity goes down for about 5 seconds, an
Encryption SAN Switch in an hacluster encounters a "VERIFY - Failed
expression" and ffdc is generated.
Supportsave: USB: interactive mode stores all files illegally in switch
root directory instead of the USB device.
Port Admin: Port Binding should disable 'Auto Mode' when the port
is part of a 256 area type that does not support auto mode.
Data miscompare seen when the data is written using a KV key, and
read using a cache key.
Overnight run of HAfailover test in large fabric caused a panic on DC
SAN Director.
QoS can be disabled on ports on 4Gb platforms, but then it cannot
later be reenabled to run QoS.
Port Admin : Port Swap does not warn the user the ports will be dis-
abled.
If switches in an edge fabric have the Principal Priority set to non-default
values, updating firmware on the FCR switch may result in fabric re-
configuration and momentary traffic disruption.
pending merge: fail to recover data with error: ERROR, SYS, FPGA
timeout, DECRYPT_DECOMPRESS_TIMEOUT : Cmd 0x932b4000.
FICON XRC times out on 400 multiprotocol router to DC SAN Director.
Need more info in configuration upload/download process.
Sfpshow displays incorrect values for current, RX power, and TX power.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Disable the DEK cache and always
use the key vault.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Do not set the principal priority of
switches in edge fabric to non default
value in a routed MetaSANs.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Toggle (enable / disable) all disabled
ports in order to restart SFP polling.