HP StorageWorks 1606 - Extension SAN Switch Release Note page 58

Hp storageworks fos 6.3.0b release notes (5697-0360, april 2010)
Hide thumbs Also See for StorageWorks 1606 - Extension SAN Switch:
Table of Contents

Advertisement

DC SAN Director: configdownload: simple upload/download (switch
enabled) complaining about FID 128 and will not download with
switch enabled.
Switch Admin: CEE: NPE is shown in error message when user applies
a new FCoE login group (with Login management disabled.)
pertperfshow does not display decimal data if overall throughput ex-
ceeds 10Gbps.
A switch restart causes random ICL E-Ports to come up "segmented."
When running FCoE traffic, debug_csock_read_header failures mes-
sage displays.
Fabric Watch: The FRU status does not auto-refresh after removal/in-
sertion of the FRU.
FCoE frames from any SMAC are incorrectly passed to the FC side.
Switchname mismatch between GUI display and CLI.
Issues with Brocade MIB objects with ifSpeed returns wrong value,
ifOutUcastPkts, ipAdEntReasmMaxSize, ipRouteAge, ipRoutingDiscards,
snmpSilentDrops, snmpProxyDrops needs to be documented.
After cfgdefault and migration from Interopmode 0 to Interopmode 2,
all switches are setting idid bit in ESA, when idid is not enabled.
Syshutdown: execution of command in current build yields only "this
is a unknown system" string on session consoles.
Cannot use "fwconfigure" to view the information on internal F/FL
ports (Copper).
Internal routes are not being configured.
Port state mismatch on internal copper ports on Embedded platforms
between switchshow and portcfgshow's PersistentDisable flag.
The Distribute Policy option is missing from the SCC and DCC tabs in
web mgmt.
Supportshow cli command output should complete without having to
hit CR several times.
58
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
User has to execute the CLI command
fcoelogincfg before using WebTools
to create the login groups.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Port toggle when it gets segmented.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Close and re-open Fabric Watch.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Fabric can be merged by disabling
the switches and setting idid mode in
the switch configurations, then
bringing the switches online. This
option is applicable only in the event
the user wishes to merge the switch
to a fabric that also has idid set.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks fos 6.3.0b

Table of Contents