In a large fabric (50+ switches), simultaneously disabling and enabling
all switches could result in some switches stuck in F2 (unconfirmed)
state.
In some rare scenarios, when HA Failover performed prior to Name
Server being in sync, RSCNs were delivered.
Test tool reports data miscompare during an overnight run.
Need for synchronization between DCBX FCoE priorities with that of
PFCs enabled.
FrustatusChanged trap and fruhistorytrap are not received when a slot
is removed or inserted.
Encrypted LUN gets into internal Encryption Engine (EE) LUN State:
Disabled (key not in sync) as a result of rekeying and HAC/DEK cluster
failover and failback.
As a result of I/O and crypto operations, three LUNs are in "Key ID
Unvailable" state and one LUN indicates that inquiry failed.
DMM used license can be reset after netinstall of FOS.
4Gb SAN Switch for HP c-Class BladeSystem AG may login to DC
SAN Director with wrong pwwn.
OpenVMS init command is not correctly supported.
In FOS 6.2, OID for connUnitType no longer returns the correct access
gateway mode status.
System panic on stand by cp after a hafailover.
Default Fabric Watch alarm value needs to be modified.
Port fence disabled ports that are running diagtest and triggered blade
fault during blade POST.
Addressing mode NVP is not available in switch.html page.
Class 2 ACK is not forwarded from F_Port to N_Port in Access Gate-
way.
MS Platform dB is activated after warm recovery of firmwaredownload.
Inconsistencies seen for topologyshow and islshow bandwidth on 8/80
and 8/8 or 8/16 switches.
Fixed in FOS 6.3.0
Workaround prior to code change:
Disable and enable the switches that
are stuck in F2 (domain ID not yet
confirmed) state independently.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Reboot the Encryption Engine (EE).
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Reboot AG.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0