In Access gateway mode,Port swap and Enable/Disable NPIV option
is enabled in WebTools.
As DCFM polling LUNs, the memory usage for weblinker is increased.
FDMI: fdmid crashes when a brocade HBA with virtual ports is connec-
ted to a 4/256 SAN Director.
Brocade 8000 firmware download hot code load shows no identifier
in the HTML page.
Unable to activate a new PDCM Matrix with WebTools.
VCM don't have GUI capability to change SNMP read community
configuration.
8/80 SAN Switch: Removing any power supply FRU causes fans to
speed up for a short period (which is not expected).
The SFP parameters are not returning for the ports which are under
the logical switches other than the default logical switch.
ptsupportshow -all does not function properly.
WEBLINKERFCGD core files after weekend SAK/IRNDUP run on DC04
SAN Director.
Applications cannot distinguish between Multiprotocol Router Blade
and Core blades on DC SAN Director using SNMP. Need to add two
new FRU classes: "coreblade" and "applicationblade" class.
Switch panic in ficon enviormnet when blocking/unblocking E-Port due
to RNID data count is incorrect.
Switch Admin: when user moves to a different tab without applying
changes, no warning is displayed.
Performance Monitoring: Error message is shown when launching
SCSI Read/Write on a LUN Per port graph.
Enabled minimum FOS support for DWDM-SFP port media.
Re-keys are getting stuck.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Logout all the devices registered their
HBA info and log them in after the
fabric is stable.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Activate the same PDCM Matrix from
WebTools, with "Active=Save Mode"
checked from 'Edit CUP Port
Connectivity Configuration' window.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Specify the slot number for which the
command is directed. For example,
ptsupportshow 1 -all command to see
all ports on blade 1.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0