Switch Admin: Policies which are not chosen are showned in confirm-
ation page of ACL Policy configuration wizard.
When attempting to swap ports from the GUI, the operation may fail
due to HTTP 500 error.
Agd aborted due to *** glibc detected *** free(): invalid next size
(fast).
DWDM link unable to sync up before port is enabled at correct speed.
Bad SFP triggered i2c access cause issues on port/slot disaplay and
cpu load on 4/256 SAN Director.
Cryptocfg show transshow when issued without any outstanding
transactions displayed Operation "failed" with an incorrect cause.
Sequence of creating two TI zones, not saving the change and then
modifying the attributes with the "zone --add" command results in
misconfigured attributes that will cause software verify on remote
switches when changes are commited.
Specific call to CEE library results in gradual memory leak.
Getting ms_ficon errors on console of core DC SAN Director in
McDATA interop after reboots.
Configdownload fails with Lsan tag download failed: Duplicate tag.
In Interopmode 2 mode, FC address is shown without offset in
switch.html and portshow (cli), but shown with offset in switchshow.
Ipaddrset command to set Lance GE ports IP address is non-responsive.
Must reboot active CP to activate IP.
Optimized SERDES setting for Brocade 8Gb SAN Switch for
BladeSystem c-Class.
60
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Other methods of creating TI Zones
and modifying the definitions work
seamlessly. Its just this odd set of steps
which produce the failing condition.
When creating multiple TI zones, they
should be saved before modifying the
attributes. Can clean up problem by
using zone --add to modify the
attributes again after the save. Can
also delete and recreate TI zone.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
Use CLI to add the tag names back
onto the FCR switch.
Fixed in FOS 6.3.0
Fixed in FOS 6.3.0
Workaround prior to code change:
The following should work. Following
any removal or relocation of an
encryption blade from any chassis
slot, do an hafailover to cause the
standby CP to become active. This
should be done even if no change in
chassis IP addresses is required as
other problems could be otherwise
encountered, depending on network
configuration.
Fixed in FOS 6.3.0