Continuous Detection Time For Remote Switching - Kyocera FS-1128MFP Service Manual

Service manual
Hide thumbs Also See for FS-1128MFP:
Table of Contents

Advertisement

2JN
Maintenance
item No.
Setting the reference for RTN signal output
U633
Sets the error line rate as the reference for RTN signal output. If transmission errors occur frequently due to
(cont.)
the quality of the line, they can be reduced by lowering this setting.
1. Select the setting using the cursor up/down keys.
Display
5%
10%
15%
20%
Initial setting: 15%
2. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting communication control 5
U634
Description
Sets the maximum number of error bytes judged acceptable when receiving a TCF signal. Used as a measure
to ease transmission conditions if transmission errors occur.
Method
1. Press the start key.
2. Change the setting using the cursor left/right keys or numeric keys.
Description
Number of allowed error bytes when detecting TCF
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting communication time 1
U640
Description
Sets the detection time when one-shot detection is selected for remote switching. (This setting item will be dis-
played, but the setting made is ineffective.)
Sets the detection time when continuous detection is selected for remote switching. (This setting item will be
displayed, but the setting made is ineffective.)
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Display
TIME (ONE)
TIME (CONT)
3. Change the setting using the cursor left/right keys or numeric keys.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-58
Description
Description
Error line rate of 5%
Error line rate of 10%
Error line rate of 15%
Error line rate of 20%
Description
Sets the one-shot detection time for remote
switching.
Sets the continuous detection time for remote
switching.
Setting range
Initial setting
0 to 255
0
Setting
Initial
range
setting
0 to 255
7
0 to 255
80

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-2820

Table of Contents