U634 Setting Communication Control; U640 Setting Communication Time; Setting The One-Shot Detection Time For Remote Switching; Setting The Continuous Detection Time For Remote Switching - Kyocera ECOSYS M2030dn/PN Service Manual

Service manual for all in one printer
Hide thumbs Also See for ECOSYS M2030dn/PN:
Table of Contents

Advertisement

Item No.
U634
Setting communication control 5
Description
Sets the maximum number of error bytes judged acceptable when receiving a TCF signal. Used
as a measure to ease transmission conditions if transmission errors occur.
Setting
1. Press the start key.
2. Change the setting using the cursor left/right keys or numeric keys.
Description
Number of allowed error bytes when detecting TCF
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U640
Setting communication time 1
Description
Sets the detection time when one-shot detection is selected for remote switching. (This setting
item will be displayed, but the setting made is ineffective.)
Sets the detection time when continuous detection is selected for remote switching. (This setting
item will be displayed, but the setting made is ineffective.)
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Display
TIME (ONE)
TIME (CONT)

Setting the one-shot detection time for remote switching

1. Change the setting using the cursor left/right keys.
Description
One-shot detection time for remote switching
2. Press the start key. The value is set.

Setting the continuous detection time for remote switching

1. Change the setting using the cursor left/right keys.
Description
Continuous detection time for remote switching
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Sets the one-shot detection time for remote switching.
Sets the continuous detection time for remote switching.
1-3-60
2PK/2PL/2PM/2PN
Setting range
Initial setting
0 to 255
0
Setting range
Initial setting
0 to 255
7
Setting range
Initial setting
0 to 255
80

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents