1-5-9
PWBs
(1) Detaching and refitting the control PWB
Procedure
1. Remove the FAX PWB (See page 1-5-50).
2. Remove the right cover (See page 1-5-3).
3. Remove the five connectors from the scan-
ner PWB.
4. Remove twenty connectors and two FFCs
from the control PWB.
5. Remove the wires from the clamp.
Connectors
Scanner PWB
Control PWB
(FFC)
YC6
YC28
YC29
Connectors
Figure 1-5-59
YC104
YC108
YC105
Scanner PWB
Wires
Control PWB
Clamp
(FFC)
YC7
YC3
YC8
FFCs
2JN
YC109
YC101
YC19
1-5-39