2JN
Maintenance
item No.
Setting the target
U425
Description
Enters the lab values that is indicated on the back of the chart (P/N: 302FZ56990) used for adjustment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Display
N875
N475
N125
CYAN
MAGENTA
YELLOW
RED
GREEN
BLUE
ADJUST ORIGINAL
3. Select the item to be set using the cursor up/down keys.
Display
L
a
b
4. Enters the value that is indicated on the back of the chart using the cursor left/right keys or numeric
keys.
5. Press the start key. The value is set.
6. To return to the screen for selecting an item, press the stop key.
Setting: [ADJUST ORIGINAL]
1. Measure the distance from the left edge to the black belt (a) of the original at A, B and C.
Measurement procedure
1) Measure the distance from the edge to the black belt (a) of the original at A (30 mm from the leading
edge), B (148.5 mm from the leading edge) and C (267 mm from the leading edge), respectively.
2) Apply the following formula for the values obtained: ((A + C) / 2 + B) / 2
2. Enter the values solved using the cursor left/right keys or numeric keys in [MAIN].
3. Press the start key. The value is set.
4. Measure the distance from the leading edge to the black belt (b) of the original at D, E and F.
Measurement procedure
1) Measure the distance from the edge to the black belt (b) of the original at D (35 mm from the left
edge), E (110 mm from the left edge) and F (185 mm from the left edge), respectively.
2) Apply the following formula for the values obtained: ((D + F) / 2 + E) / 2
5. Enter the values solved using the cursor left/right keys or numeric keys in [SUB LEAD].
6. Press the start key. The value is set.
7. Measure the length (G) from the edge of the black belt (b) to edge of the black belt (c) of the original.
8. Enter the measured value using the cursor left/right keys or numeric keys in [SUB TAIL].
9. Press the start key. The value is set.
10. To return to the screen for selecting an item, press the stop key.
1-3-46
Description
Description
Setting the N875 patch for the original for adjustment
Setting the N475 patch for the original for adjustment
Setting the N125 patch for the original for adjustment
Setting the cyan patch for the original for adjustment
Setting the magenta patch for the original for adjustment
Setting the yellow patch for the original for adjustment
Setting the red patch for the original for adjustment
Setting the green patch for the original for adjustment
Setting the blue patch for the original for adjustment
Setting the main and auxiliary scanning directions
Description
Setting the L value
Setting the a value
Setting the b value
Setting range
0.0 to 100.0
-200.0 to 200.0
-200.0 to 200.0