Setting The Frequency Of The Ced Signal; Setting The Waiting Period To Prevent Echo Problems At The Receiver; Setting Ecm Reception - Kyocera FS-1128MFP Service Manual

Service manual
Hide thumbs Also See for FS-1128MFP:
Table of Contents

Advertisement

Maintenance
item No.

Setting the waiting period to prevent echo problems at the receiver

U630
Sets the period before an NSF, CSI or DIS signal is sent after a CED signal is received. Used when problems
(cont.)
occur due to echoes at the receiver.
1. Select the setting using the cursor up/down keys.
Display
500
75
Initial setting: 75
2. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting communication control 2
U631
Description
Makes settings regarding fax transmission.
Start
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Display
ECM TX
ECM RX
CED FREQ.
Setting ECM transmission
To be set to OFF when reduction of transmission costs is of higher priority than image quality.
This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line.
1. Select the setting using the cursor up/down keys.
Display
ON
OFF
Initial setting: ON
2. Press the start key. The setting is set.

Setting ECM reception

To be set to OFF when reduction of transmission costs is of higher priority than image quality.
This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line.
1. Select the setting using the cursor up/down keys.
Display
ON
OFF
Initial setting: ON
2. Press the start key. The setting is set.

Setting the frequency of the CED signal

Sets the frequency of the CED signal. Used as one of the measures to improve transmission performance for
international communications.
1. Select the setting using the cursor up/down keys.
Display
2100
1100
Initial setting: 2100
2. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Sends an NSF, CSI or DIS 500 ms after receiving a CED.
Sends an NSF, CSI or DIS 75 ms after receiving a CED.
Description
Sets ECM transmission.
Sets ECM reception.
Sets the frequency of the CED signal.
Description
ECM transmission is enabled.
ECM transmission is disabled.
Description
ECM reception is enabled.
ECM reception is disabled.
Description
2100 Hz
1100 Hz
2JN
1-3-55

Hide quick links:

Advertisement

Table of Contents
loading