Checking The Rest Thread Monitor - Beisler 2110-5 Working Instructions

Hide thumbs Also See for 2110-5:
Table of Contents

Advertisement

Short Seam Automat 2110-5 / 2111-5 Working Instructions
C.5
C.5.5 Machine set-up

Checking the rest thread monitor:

The rest thread monitor is checked using a photocell. If
the messages on the display do not match the filling state
of the spool, the photocell sensitivity must be checked.
1. Fig. 21: Fill bobbin to half its capacity so that filling state
indicators
of upper chamber
2. Insert bobbin and sew until display shows:
BOBBIN: 003 M.
Keep sewing until display shows: BOBBIN EMPTY
3. Remove spool, unwind rest thread and measure remai-
ning length (should be 0.5 m).
Adjusting the photocell:
If the thread on the spool is sewn off over the rest length
of 0.5 m without the message BOBBIN EMPTY being
displayed, the photocell sensitivity must be increased:
Rotate potentiometer at photocell in clockwise di-
rection.
If the message BOBBIN EMPTY is displayed even
though the spool contains more than 0.5 m thread, the
photocell sensitivity must be reduced:
Rotate potentiometer at photocell in counter-clo-
ckwise direction.
Maintenance
are covered.
Fig. 21
- C 49 -