Copying Variables To The Memory Stick; Loading Variables From The Memory Stick; Running Clamp Motor In Permanent Test; Testing The Thread Cutter - Beisler 2110-5 Working Instructions

Hide thumbs Also See for 2110-5:
Table of Contents

Advertisement

Beisler Automated Sewing Equipment
D.3
D.3.1 System menu

Copying variables to the memory stick

All variables (global parameters/special parameters) can be
stored on the memory stick (backup copies).
Insert memory stick into USB slot.
Press
key.
Press
key (init parameters).
Machine < -- > Stick.
Pess
key Machine memory -- > Stick.
Press
Confirm safety prompt.
Press
key.

Loading variables from the memory stick

All variables (global parameters/special parameters) can
be downloaded from the memory stick to the program con-
trol memory to reestablish the machine configuration.
Insert memory stick into USB slot.
Press
key.
Press
key (init parameters).
Machine < -- > Stick.
Pess
key Stick -- > Machine memory.
Press
Confirm safety prompt.
Press
key.
NOTE - Current configuration!
If this function is used to download all variables from the
memory stick to the program control, all current sewing
programs will be overwritten.
Programming
Short Seam Automat 2110-5 / 2111-5 Workinging Instructions
D.3.1 System menu

Running clamp motor in permanent test

The clamp motor can be run permanently to check for
constant machine movement.
Press
key.
Press
key (diagnostics).
Press
key (clamp transport).
Press
key (clamp motor permanent test).
Confirm safety prompt.
Press
key.
The clamp motor runs permanently until it is stopped. To
stop the motor:
Press key STOP.

Testing the thread cutter

By entering a three-digit value global parameter 35, you
can determine when the thread cutter is activated. The
input must be checked for a machine cycle and corrected
if required.
Press
key.
Press
key (diagnostics).
Press
key (sewing motor).
Press
key (thread cutter).
Enter value using numeric keypad.
Start or stop machine cycle.
Press
key.
- D 66 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2111-5

Table of Contents