Storage And Location Requirements; Floor Quality; Interior Climate; Floor Space Required - Beisler 2110-5 Working Instructions

Hide thumbs Also See for 2110-5:
Table of Contents

Advertisement

Beisler Automated Sewing Equipment
C.2
C.2.1 Floor quality
The floor of the room where the machine is to be instal-
led must have a sufficient surface strength. The location
of the machine must be free of vibrations.
If several machines are to be installed in one room, the
static load bearing capacity of the ceiling must be consi-
dered.
Weight:
Machine with accessories
C.2.2 Interior climate
Climatic requirements for the operating room:
The machine must only be stored or operated in closed
operating rooms.
Room temperature
Relative humidity
C.2.3 Floor space required
For operation during production and for service works, the
machine must be freely accessible from all sides. On all
sides, there must be a minimum clearance of 1 m.
Machine dimensions:
L x W x H
NOTE - Electromagnetic interference!
The machine must not be installed in the immediate vicinity
of devices or electrical components (e.g. transformers)
generating a strong magnetic field as otherwise the cor-
rect function of the program control may be impaired.

Storage and location requirements

approx 210 kg
+10 °C to +45 °C
80 % max.
1700 x 1200 x 1600 mm
Short Seam Automat 2110-5 / 2111-5 Working Instructions
C.2.4 Supply connections
The machine requires on-site power and compressed air
sources.
Power connection:
The power supply of the machine requires a properly
grounded power connection with:
Grounding plug
Fusing
NOTE - Peak voltages!
The correct function of the machine requires that the power
system supplies a constant current. Peak voltages may
particularly impair the stability of the program control.
Compressed air supply:
The on-site compressed air supply system must meet the
following requirements:
Operating pressure
Compressed air quality
Compressed air consumption
- C 30 -
230 V ± 10 %, 50/60 Hz
16 A
6 bar
oil-free
4.16 NL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2111-5

Table of Contents