Short Seam Automat 2110-5 / 2111-5 Workinging Instructions
D.4
D.4.1 Factory settings for global parameters
M01 Global parameters 2111-5
Pos.
global parameters 2111-5
01
Till CLAMP SIDEWAYS FWD
02
TILL CLAMP DOWN
03
TILL VACUUM OFF
04
THREAD LENGTH spool full
05
TILL CLAMP INSERTING
06
SEWING END ->CL.SIDEW.
07
TIME AFTER CLAMP OPEN
10
TILL FOLDING CL. CLOSED
11
TILL FOLDER LIFT UP
12
TILL FOLDER SWINGS LEFT
13
IMPULS FOLDER DOWN
14
CL.OPEN TILL FOLDER UP
17
TILL TENSION OPEN
18
DURATION OF TENS. OPEN
19
TILL THREAD CLAMP FORW
20
DUR.THREAD CLAMP FORW
21
TILL STACKER TRANSPORT
22
DUR.SLIDING TABLE OPEN
23
LIFT.TABLE MOD 00/01-99
24
DUR.LIFTING TABLE SINKS
25
TILL FABRIC CLAMP FORW.
26
TILL SCISSORS CLOSED
27
DURATION SCISSORS CUTS
28
TILL FABRIC CLAMP OPEN
29
TILL SWING RETAINER DWN
30
TILL RETAINER SWINGS
31
DUR. OF PULLING RETAINER
32
BLOW OUT THE PART
33
TILL THRUST FOR REMOVAL
35
THREAD CATCH. "UP" POS
36
SWITCH ON POS.OF TRIMM
37
TRIMMING SPEED
38
DURATION OF TRIMMING
39
THREAD CATCH.TURNS BACK
40
PROCESS IN STEPS
Factory settings
Value
Unit
0.0
sec
0.2
sec
0.0
sec
003
m
0.1
sec
0.0
sec
0.1
sec
0.5
sec
0.3
sec
0.3
sec
0.04
sec
0.20
sec
0.00
sec
0.5
sec
0.1
sec
0.5
sec
0.0
sec
0.8
sec
00
0.99
sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
0.0
sec
200
INC
100
INC
180
Upm
0.35
sec
00
INC
00
- D 85 -
Beisler Automated Sewing Equipment