Photocell Light Sensitivity Setting - Beisler 2110-5 Working Instructions

Hide thumbs Also See for 2110-5:
Table of Contents

Advertisement

Beisler Automated Sewing Equipment
C.5
C.5.5 Machine set-up

Photocell light sensitivity setting:

The photocell
at the sewing head controls the begin-
ning and the end of the sewing process.
The sensitivity of the photocell must be set in accordance
with the sewing material used.
This function must be adjusted correctly (see section
D.3.2).
1. Fig. 18: Make sure that the light beam
tocell is not interrupted.
2. Unlock the keypad:
Keep the two buttons
approx 5 seconds.
The green LED
illuminates momentarily to indicate
the unlocked state. The keypad remains unlocked for
4 minutes (red LED
controller is locked automatically.
3. Set sensitivity using buttons
Press + to increase sensitivity.
Press - to reduce sensitivity.
4. Interrupt light beam
used
; if the yellow LED
sensitivity.
NOTE - Red LED!
The red LED
must not illuminate in any switching state.
If the red LED illuminates, the light amplifier is in a criti-
cal switching state. In this case, increase the photocell sen-
sitivity until the red LED goes off, then set the sensitivity
in accordance with the sewing material used as descri-
bed above.
Maintenance
of the pho-
and
(+ / -) depressed for
flashes), then the light guide
and
:
with the sewing material to be
fails to go off, reduce
Short Seam Automat 2110-5 / 2111-5 Working Instructions
Fig. 18
- C 46 -
Fig. 18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2111-5

Table of Contents