Upgrading A Processor - HP ML570 - ProLiant - G2 Setup And Installation Manual

Hp proliant ml570 generation 2 server setup and installation guide
Hide thumbs Also See for ML570 - ProLiant - G2:
Table of Contents

Advertisement

18. Reinstall the access panel.
19. Install the server. Refer to Chapter 5, "Installing the Rack Server" or Chapter 6,
"Installing the Tower Server."
20. Power up the server. Refer to Chapter 5, "Installing the Rack Server" or
Chapter 6, "Installing the Tower Server."
NOTE: The ROM sets the processing frequency during the Power On Self Test (POST).
21. Be sure that the internal health LED on the front of the system is illuminated
green, indicating that the system is functioning properly. For detailed information
on LEDs, refer to Appendix C, "System LEDs and Switches."
22. If the LED indicates an error, refer to Appendix D, "Troubleshooting," or refer to
the troubleshooting guide for instructions.

Upgrading a Processor

CAUTION: To be sure that the system ROM recognizes the new processor you are
installing, update the ROM if necessary. For the most recent ROMpaq, refer to the
website:
www.hp.com/servers/proliant/manage
Failure to flash your ROM before installing processors can cause system failure.
CAUTION: Processor socket 1 and PPM slot 1 must always be populated. Failure to
populate processor socket 1 and PPM slot 1 prevents the system from operating.
IMPORTANT: Install a PPM for each processor in the system. When installing a new
processor, you must also install a new PPM.
IMPORTANT: If processors of differing speeds are installed, each processor matches the
rated speed of the slowest processor. For optimal performance, upgrade all processors at the
same time, rather than mixing processor speeds.
IMPORTANT: The servers ship with green-colored processor/heatsink assemblies. To be
sure that you install a processor compatible with the server, only install processors with
green-colored heatsinks.
HP ProLiant ML570 Generation 2 Server Setup and Installation Guide
Installing Hardware Options
3-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant ml570 g2

Table of Contents