Troubleshooting
7. Check the server for the following normal power-up sequence to be sure that
your system meets the minimal hardware requirements and is powered up during
normal operations:
a. The power button LED turns from standby (amber) to on (green).
b. The fans start up.
8. Check the monitor for the following messages that verify your system meets the
minimal hardware requirements and is powered up during normal operations:
a. HP ProLiant logo
b. BIOS information
c. Copyright information
d. Processor initialization
e. Multi-initiator configuration
IMPORTANT: Select the multi-initiator configuration utility (CRTL-A) only to support HP
storage and clustering options. Refer to Chapter 8, "Server Configuration and Utilities," for
additional information.
f. PXE initialization
g. Option ROMs
h. SCSI devices
The operating system loads to complete the boot process.
If the server completes POST and attempts to load the operating system, go to the
"Problems After Initial Boot" section in this appendix.